Wednesday, August 29, 2012

Jual Overload Current Relays for Motor TeSys LR97D015F7 Schneider











Keterangan:Main
Range of product INF32
INFD40
Fuse switch name INFD40
Poles description 3P
Protected poles description 3f
Fuse type DIN
Fuse size NH000
Network type AC
DC
Network frequency 50/ 60 Hz
Rotary handle mounting location Front
[ Ie] rated operational current DC-21B: 40 A DC 440 V 4 poles in series
DC-23B: 40 A DC 220 V 4 poles in series
DC-22B: 40 A DC 220 V 2 poles in series
AC-23A: 40 A AC 50/ 60 Hz 660/ 690 V
AC-23A: 40 A AC 50/ 60 Hz 500/ 525 V
AC-23A: 40 A AC 50/ 60 Hz 440/ 480 V
AC-23A: 40 A AC 50/ 60 Hz 380/ 415 V
AC-23A: 40 A AC 50/ 60 Hz 220/ 240 V
AC-22A: 40 A AC 50/ 60 Hz 660/ 690 V
AC-22A: 40 A AC 50/ 60 Hz 500/ 525 V
AC-22A: 40 A AC 50/ 60 Hz 440/ 480 V
AC-22A: 40 A AC 50/ 60 Hz 380/ 415 V
AC-22A: 40 A AC 50/ 60 Hz 220/ 240 V
[ Ith] conventional free air thermal current 40 A ( 35 ° C ) horizontal
36 A ( 45 ° C ) horizontal
34 A ( 50 ° C ) vertical
40 A ( 40 ° C ) vertical
38 A ( 45 ° C ) vertical
36 A ( 40 ° C ) horizontal
34 A ( 55 ° C ) vertical
32 A ( 60 ° C ) vertical
32 A ( 50 ° C ) horizontal
30 A ( 65 ° C ) vertical
30 A ( 55 ° C ) horizontal
28 A ( 70 ° C ) vertical
28 A ( 60 ° C ) horizontal
26 A ( 65 ° C ) horizontal
24 A ( 70 ° C ) horizontal
[ Ithe] conventional enclosed thermal current 40 A ( 40 ° C ) / Power dissipation per fuse: 4.5 W 300 mm x 350 mm x 200 mm
[ Ui] rated insulation voltage 1000 V DC
1000 V AC 50/ 60 Hz
[ Uimp] rated impulse withstand voltage 12 kV
[ Ue] rated operational voltage 690 V DC DC-20
690 V AC 50/ 60 Hz AC-20
690 V AC 50/ 60 Hz
250 V DC
Suitability for isolation Yes
Contact position indicator Yes
Visible break No
Pollution degree 3
Complementary
Control type Without handle
Rotary handle mounting style Direct
Extended
Provision for padlocking Padlockable
Mounting mode Vertical – horizontal
Mounting support DIN rail
Mounting plate
Maximum power 18.5 kW 415 V AC 50/ 60 Hz
18.5 kW 380/ 400 V AC 50/ 60 Hz
30 kW 660/ 690 V AC 50/ 60 Hz
22 kW 500/ 525 V AC 50/ 60 Hz
11 kW 220/ 240 V AC 50/ 60 Hz
Rated duty Uninterrupted
Intermittent duty class Class 120 – 60 %
Rated making and breaking capacity Icm 7.5 kA 500 V without fuse
Icn 80 kA conforming to BS 415 V with fuse
Icn 50 kA conforming to DIN 690 V with fuse
Icn 100 kA conforming to DIN 500 V with fuse
Icm 9 kA 415 V without fuse
Icm 6 kA 690 V without fuse
Icm 220 kA conforming to DIN 500 V with fuse
Icm 176 kA conforming to BS 415 V with fuse
Icm 105 kA conforming to DIN 690 V with fuse
Mechanical durability 10000 cycles
Electrical durability AC-23A: 1500 cycles 690 V AC 50/ 60 Hz
AC-23A: 1500 cycles 500 V AC 50/ 60 Hz
AC-22A: 1500 cycles 690 V AC 50/ 60 Hz
AC-22A: 1500 cycles 500 V AC 50/ 60 Hz
[ Icw] rated short-time withstand current 0.57 kA ( 3 s )
0.22 kA ( 20 s )
0.18 kA ( 30 s )
1 kA ( 1 s )
Connections – terminals Tunnel type terminal 0.5… 10 mm² rigid
Tunnel type terminal 0.5… 10 mm² flexible
Tightening torque Terminal: 2 N.m
Height 100 mm
Width 114.5 mm
Depth 120.5 mm
Environment
Standards EN/ IEC 60269-1
EN/ IEC 60269-4
EN/ IEC 60947-1
EN/ IEC 60947-3
EN/ IEC 60947-5
Product certifications CCC
IP degree of protection IP65 conforming to IEC 60529
IP20 conforming to IEC 60529
IK degree of protection IK10 conforming to EN 50102
IK07 conforming to EN 50102
Ambient air temperature for operation -25… 70 ° C
Ambient air temperature for storage -50… 85 ° C
Offer Sustainability
Sustainable offer status Not Green Premium product
RoHS Compliant – since 1001 – Schneider Electric declaration of conformity

No comments: